Offer
MC RW
- the MC RW roof window is a solution based on the MC Wall facade system; this type of structures is used to design ventilation flaps
- the MC RW is a three chamber system with thermal insulation; it is optional to use an additional insulating components to improve thermal aspects of the structure (under-glass inserts, inserts between thermal separators)
- the structure can be installed on roofs with the pitch ranging from 5° to 75° relative to the horizontal
- the MC RW roof window is fitted with an effective drainage and ventilation system integrated with the mullion-transom wall system
- the window weight is limited by technical parameters of the applied opening mechanisms and hinges; the weight can be up to 150 kg
- the MC RW structure can be used with a wider range of closers available on the market; the MC RW roof window can be fitted with a manual or electrical opening mechanism
- optional to use glazing units with the thickness from 28 to 46 mm
- a wide range of colours – RAL palette (Qualicoat 1518), texture colours, Aliplast Wood Colour Effect (wood-like colours), Aliplast Loft View – colours imitating stone surfaces (Qualideco PL-0001), anodised colour (Qualanod 1808), bi-colour
- maximum structure dimensions:
2120 x 1120 mm - maximum total pane area: 1,9 m2
(for this overall dimensions it is possible to use 6 ESG/16/442 glass)
970 x 2070 mm – maximum total pane area: 3,48 m2
TECHNICAL SPECIFICATION
SYSTEM |
MATERIAL |
DEPTH OF FRAME | DEPTH OF LEAF | GLAZING RANGE | TYPE OF WINDOWS | TYPE OF GLAZING |
MC RW | aluminium/ polyamid |
87 mm |
81 mm | 28-56 mm | roof window | glazing strip |
PERFORMANCE
SYSTEM |
THERMAL INSULATION UF* |
AIR PERMEABILITY |
WINDLOAD RESISTANCE | WATERTIGHTNESS |
MC RW |
Uf from 1,70 W/m2K |
Class 4; EN 12207 | CE/BE 2400; EN 12210 | Class E2100; EN 12208 |
*Thermal insulation is dependent on a combination of profiles and thickness of the filling
Enter the phone number to get the SMS code to access the file